Water Heater Element Resistance Calculator
Enter the watts and volts stamped on an element and get the resistance and current a good one should show.
Also check each terminal to the tank with the meter on ohms. Any continuity to the tank means the element is grounded and must be replaced, even if its resistance reads right.
How it works
Resistance (Ω) = volts² ÷ watts · Current (A) = watts ÷ volts · Watts on another supply = supply volts² ÷ resistance
These are Ohm's law, nothing brand-specific. Use the voltage stamped on the element with its wattage, which is not always the voltage on site.
Common elements
| Element | Expected resistance | Current at rated volts |
|---|---|---|
| 1,500 W, 120 V | 9.6 Ω | 12.5 A |
| 2,000 W, 120 V | 7.2 Ω | 16.7 A |
| 3,500 W, 240 V | 16.5 Ω | 14.6 A |
| 3,800 W, 240 V | 15.2 Ω | 15.8 A |
| 4,500 W, 240 V | 12.8 Ω | 18.8 A |
| 5,500 W, 240 V | 10.5 Ω | 22.9 A |
| 4,500 W, 208 V | 9.6 Ω | 21.6 A |
Testing an element
- Turn the breaker off and confirm with a meter that there is no voltage at the element before touching anything.
- Take both wires off the element so the meter reads the element alone.
- Measure across the two screws. A good element reads close to the expected value. Resistance changes a little with temperature, so don't expect an exact match.
- An open reading means the element is burned out.
- Measure from each screw to the tank. Any continuity means the element is grounded: it can heat with the thermostat off and trip the high limit.
- Never power an element that isn't covered by water. A dry-fired element fails in seconds.
Was this tool useful?
One field tip a week
A short, practical plumbing tip in your inbox every week: diagnostics, water heaters, drains and code changes. Free, unsubscribe anytime.
We'll only use your email for the newsletter. Privacy policy.
Related tools
Tankless Water Heater Sizing Calculator
Fixtures running at once and the coldest incoming water in; the BTU input a tankless heater needs out, with a check on any model's input.
GPHWater Heater Recovery Rate Calculator
Gallons per hour a gas or electric tank really recovers at your incoming water temperature, and how long a cold tank takes to heat.
$/JOBCost per Booked Job Calculator
Compare marketing channels by what a booked job really costs, not cost per lead.
Results are estimates for field reference. Always confirm against the manufacturer's installation instructions and the code adopted where you work. Found a problem with this tool? Tell us.