Water Heater Recovery Rate Calculator

How many gallons per hour a tank water heater can reheat, and how long a cold tank takes to reach setpoint.

BTU/h
%
°F
°F
gal

Enter the incoming water temperature to get the recovery rate.

How it works

Recovery (gal/h) = input (BTU/h) × efficiency ÷ (8.33 × temperature rise)

Electric input (BTU/h) = kW × 3,412

Time to heat a tank (h) = gallons × 8.33 × rise ÷ (input × efficiency)

Recovery depends on the temperature rise as much as on the burner. The same heater recovers far fewer gallons per hour in winter, when the incoming water is colder. That is why a tank that kept up in August runs out in January.

Using it

  • Rating plates often list recovery at a 90°F or 100°F rise. Enter your real incoming temperature to see what the customer actually gets.
  • Most residential electric tanks run one element at a time, so enter a single element's kW, not both added together.
  • Recovery is only half of the story on a storage heater. The first hour rating on the EnergyGuide label combines stored hot water and recovery.
  • Slow recovery on an electric tank with good elements? Check the supply voltage with the element resistance calculator.