How to Size a Water Heater: First Hour Rating and Tankless GPM
Tankless Water Heater Sizing Calculator
Enter the fixtures that run together and the coldest incoming water temperature.
"Same size as the old one" is how most water heaters get picked, and it is why a lot of them disappoint. The household changed, or the old one never kept up. Sizing takes five minutes.
Tank water heaters: first hour rating
The first hour rating is the number of gallons of hot water a heater can supply in one hour, starting with a full tank of hot water. The Department of Energy explains that it depends on the tank capacity, the heat source and the size of the burner or element. Two 50-gallon tanks can have very different first hour ratings.
Find it on the yellow EnergyGuide label, in the top left corner, as "Capacity (first hour rating)."
Peak hour demand
- Pick the hour of the day when the household uses the most hot water. For most families that is the morning.
- List what runs in that hour: showers, a bath, shaving, the dishwasher, the washer.
- Add up the gallons. As a rough guide, A. O. Smith's sizing page uses about 20 gallons per shower, more for long ones.
- Choose a heater with a first hour rating that at least matches the total.
Ask who is moving in, too. A tank sized for two retirees won't cover a family of five who buys the house.
Recovery
First hour rating already includes recovery. If you want to see recovery on its own, or what a heater does at the real incoming water temperature, use the recovery rate calculator. Recovery falls as incoming water gets colder, which is why complaints come in winter.
Tankless water heaters: flow and temperature rise
A tankless heater has no stored water to fall back on. It either keeps up with the flow or it doesn't.
- Add the flow rates of the fixtures expected to run at the same time. The Department of Energy's example: a faucet at 0.75 gpm plus a shower at 2.5 gpm needs at least 3.25 gpm.
- Find the temperature rise: setpoint minus the incoming water temperature. Use the coldest incoming water of the year.
- Match a model that delivers that flow at that rise. The heat required is about gpm × 500 × rise in BTU per hour.
The Department of Energy's guidance has put a typical figure at a 70°F rise at 5 gpm through a gas tankless and 2 gpm through an electric one. That gap is why whole-house electric tankless units struggle in cold-water regions.
The calculator above does the arithmetic and checks a model's input against the load.
Mistakes that cause callbacks
- Sizing a tankless on summer water. The unit that ran two showers in July runs one in January.
- Ignoring the gas line. A tankless unit's input is several times a tank's. The pipe and meter have to be sized for it under the fuel gas code adopted where you work.
- Reading gallons, not first hour rating. A bigger tank with a small burner can deliver less in the peak hour than a smaller tank with a larger one.
- Forgetting the big tub. A soaking tub can take most of a tank by itself. Ask about it.
- Fixing an undersized tank with the thermostat. It raises the scald risk. See temperature setting and scald times.
FAQ
What is first hour rating?
The gallons of hot water a storage water heater can deliver in an hour starting with a full hot tank. It is on the EnergyGuide label.
Is first hour rating the same as tank size?
No. It combines the stored hot water with what the burner or element can reheat during that hour.
How many gpm do I need for a tankless water heater?
Add the flow of everything that runs together. One shower and one faucet is about 3.25 gpm by the Department of Energy's example. Then check what a model delivers at your temperature rise.
Why does my tankless heater run out of capacity in winter?
Colder incoming water means a bigger temperature rise, and the same burner can only heat fewer gallons per minute through it.
Sources
Was this guide useful?
One field tip a week
A short, practical plumbing tip in your inbox every week: diagnostics, water heaters, drains and code changes. Free, unsubscribe anytime.
We'll only use your email for the newsletter. Privacy policy.
Tools for this job
Related guides
Water Heater Temperature Setting: 120°F and How Fast Hot Water Burns
The CPSC urges 120°F at the water heater. Scald times at 120, 130, 140 and 150°F, how to measure the real temperature at the tap, and when a mixing valve is the better fix.
How to Flush a Tankless Water Heater (Descaling Step by Step)
Descaling a tankless water heater with isolation valves, a pump and white vinegar: the steps, how long Rinnai and Rheem say to circulate, the rinse, and the codes that mean it's overdue.
Hot Water Smells Like Rotten Eggs: Causes and Fixes
Rotten egg odor from the hot side only comes from sulfate-reducing bacteria in the water heater, fed by the anode's reaction. How to confirm it, the chlorination and anode fixes, and why pulling the anode is the wrong answer.
Thermal Expansion Tank Precharge: How to Set It and Test the Tank
Set a potable expansion tank's air precharge to the cold water supply pressure, with the tank empty, before it goes in. Where it installs, how to check an existing tank, and the mistakes that kill them.
Field reference for trained technicians. Always follow the equipment manufacturer's instructions, local code and safe work practices. See our editorial standards, or report a correction.