How to Flush a Tankless Water Heater (Descaling Step by Step)
Scale on a tankless heat exchanger acts as insulation. The unit runs hotter to deliver the same water, flow drops, and eventually it throws a code. On Rinnai units, LC or 00 means the heat exchanger is liming up and has to be flushed.
Safety: Power and gas stay off for the whole procedure. Water in the unit may be hot; open the service ports slowly.
What you need
- Hot and cold isolation (service) valves on the heater. Rinnai strongly recommends them; without them there is no clean way to flush.
- A small submersible or utility pump and two washing-machine hoses
- A 5-gallon bucket
- About 4 gallons of undiluted, virgin, food-grade white vinegar (Rinnai's specification). Rheem's kit instructions say to use only virgin food-grade white vinegar and no other solution.
The procedure
This is the common sequence in Rinnai's manuals. Valve labels and details vary by model, so have the manual for the unit open.
- Disconnect electrical power to the water heater. Turn the gas off.
- Close the shutoff valves on both the hot and the cold water lines.
- Connect a hose from the pump outlet to the cold service port. Connect a second hose to the hot service port and drop its other end in the bucket.
- Pour the vinegar into the bucket and set the pump in it.
- Open both service valves.
- Run the pump and let the solution circulate. Rinnai: at least 45 minutes on current models; older Rinnai manuals call for at least an hour at about 4 gallons per minute. Rheem: 45 to 60 minutes, longer where the water is hard.
- Turn the pump off.
- Rinse: remove the pump hose, close the cold service port, open the cold shutoff, and let fresh water run through the heater and out the hot service hose for five minutes.
- Close the hot service port and open the hot shutoff. Disconnect the hoses.
- Pull and clean the cold water inlet filter.
- Restore power and gas, run a hot tap and check for leaks.
Model differences that matter:
- Rheem, Ruud, Richmond and Paloma: the electronic bypass valve inside the heater has to be closed before flushing. The flush kit instructions give the steps.
- Rinnai Sensei: Technical Bulletin TB-188 has a procedure for positioning the internal control valves for flushing.
- Some older Rinnai manuals tell you to call technical support for a board reset after the flush.
How often
Rinnai's guidance is at least once a year. Hard water needs it more often. If a unit limes up again within months, the fix is water treatment ahead of the heater, not more vinegar.
FAQ
How long do you circulate vinegar through a tankless water heater?
Rinnai's current manuals say at least 45 minutes and older ones at least an hour. Rheem's flush kit says 45 to 60 minutes. Go by the manual for the model.
Can I use something stronger than vinegar?
Use only what the manufacturer allows. Rheem's kit instructions say white vinegar and nothing else. Rinnai specifies food-grade white vinegar, and Rinnai New Zealand's procedure also allows citric acid.
Can you flush a tankless heater without isolation valves?
Not properly. Install a service valve kit first; it pays for itself on the first maintenance visit.
What does LC mean on a Rinnai?
LC, or 00 on some models, means scale is building up in the heat exchanger and the unit needs to be flushed.
Sources
- Rinnai, 13-Step Tankless Water Heater Flushing Procedure
- Rinnai RUC80i manual, heat exchanger flush procedure
- Rinnai RL75e manual, Flushing the Heat Exchanger (Error Code: LC or 00)
- Rinnai Technical Bulletin TB-188, Sensei Enhanced Flush Procedure
- Rinnai New Zealand, Infinity vinegar flush procedure
- Rheem Tankless Flush Kit Flushing Instructions (AP14429-2)
Was this guide useful?
One field tip a week
A short, practical plumbing tip in your inbox every week: diagnostics, water heaters, drains and code changes. Free, unsubscribe anytime.
We'll only use your email for the newsletter. Privacy policy.
Related guides
How to Size a Water Heater: First Hour Rating and Tankless GPM
Size a tank water heater by first hour rating against peak hour demand, and a tankless by flow rate and temperature rise. The Department of Energy's method, where to find the numbers, and the mistakes that cause callbacks.
Water Heater Temperature Setting: 120°F and How Fast Hot Water Burns
The CPSC urges 120°F at the water heater. Scald times at 120, 130, 140 and 150°F, how to measure the real temperature at the tap, and when a mixing valve is the better fix.
Hot Water Smells Like Rotten Eggs: Causes and Fixes
Rotten egg odor from the hot side only comes from sulfate-reducing bacteria in the water heater, fed by the anode's reaction. How to confirm it, the chlorination and anode fixes, and why pulling the anode is the wrong answer.
Thermal Expansion Tank Precharge: How to Set It and Test the Tank
Set a potable expansion tank's air precharge to the cold water supply pressure, with the tank empty, before it goes in. Where it installs, how to check an existing tank, and the mistakes that kill them.
Field reference for trained technicians. Always follow the equipment manufacturer's instructions, local code and safe work practices. See our editorial standards, or report a correction.