Home / Checklists / Tank water heater maintenance

Tank Water Heater Maintenance Checklist

Annual service checklist for gas and electric tank water heaters, with spaces for pressure, temperature and expansion tank readings.

Use it on an annual visit or before quoting a replacement. The readings are the ones that explain most hot water complaints.

The water heater manufacturer's instructions and the code adopted where you work come first.

Saves on this device as you type. Nothing is sent to us.
Job
Equipment
Before you start
Customer's complaint and hot water habits noted
Area around the heater clear; no stored flammables
No signs of leaking at the tank, fittings, drain valve or relief valve
Drain pan present where required and its drain is clear
Water side
Static water pressureNothing runningpsi
Highest pressure during a heating cycleGauge with a lazy hand; a big climb means thermal expansionpsi
Hot water temperature at the nearest tapThermometer in a cup after a few minutes of flow°F
Thermostat setting confirmed with the customer
Cold shutoff valve works and holds
Tank flushed at the drain valve until clear
Anode rod inspected or replacement recommendedWhere it is accessible
Hot water odor checked (hot side only vs. hot and cold)
Relief valve and expansion tank
T&P relief valve lever operated; water flows and the valve reseatsIf no water flows, shut the heater off
Relief valve discharge pipe full size, pitched down, not capped or valved
Relief valve age noted; removal and inspection recommended if past the manufacturer's interval
Expansion tank air chargeSystem pressure at zero; should match the cold supply pressurepsi
Expansion tank supported and not waterlogged
Gas heaters
Burner and pilot or igniter clean; flame steady
Combustion air openings and the intake screen clear
Vent connector secure, pitched up, no corrosion or backdraft signs
Draft checked at the hood with the heater firing
Gas shutoff, sediment trap and connector in good condition; joints leak-checked
Carbon monoxide alarm present near sleeping areas
Electric heaters
Power off and verified dead before removing covers
Supply voltageV
Upper element resistanceWires off the elementΩ
Lower element resistanceWires off the elementΩ
No continuity from either element to the tank
Wiring connections tight; no heat damage; covers and insulation back in place
Wrap-up
Heater returned to service and cycled
No leaks after refilling; air bled at a hot tap
Findings and recommendations reviewed with the customer
Notes and recommendations

Why the pressure readings matter

A relief valve that drips is usually reporting thermal expansion. Static pressure and the peak during a heating cycle tell you whether the house needs an expansion tank, a pressure reducing valve or both. See T&P relief valve leaking and expansion tank precharge.

Element readings

Compare each element with what its stamped watts and volts should read in the element resistance calculator.

Sources

More checklists

General good practice for field reference. The equipment manufacturer's instructions and local code always come first. Suggest an improvement: hello@plumbingcheatsheet.com.